Core question · Read distances from a ruler
On a TLC plate the baseline lies at 1.2 cm on a ruler, the middle of a sample spot at 3.4 cm and the solvent front at 6.7 cm. Calculate the Rf value. Explain why 3.4 ÷ 6.7 would be unsuitable.
Show a clue
Measure how far the spot and solvent moved from where they started.
Show the worked answer
The spot moves 3.4 − 1.2 = 2.2 cm and the front moves 6.7 − 1.2 = 5.5 cm. Rf = 2.2 ÷ 5.5 = 0.40. The original marks measure positions, so subtract the baseline position from each.
Harder question · Compare corrected concentrations
In a gas chromatogram, the peak area is 240 for X and 300 for Y. Their calibration slopes are 80 and 150 area units per mg dm⁻³ respectively, with zero intercepts. Which compound has the higher concentration, and what is the ratio X:Y?
Show a clue
Convert each area with its own calibration slope before comparing the concentrations.
Show the worked answer
X = 240 ÷ 80 = 3.0 mg dm⁻³. Y = 300 ÷ 150 = 2.0 mg dm⁻³. X has the higher concentration, and X:Y = 3:2.